Accutest Dengue NS (10 Tests)


10 Test

1,553

AccuTest Dengue NS1 Antigen Test AccuTest
Dengue NS1 Antigen test is rapid and qualitative test for the detection of dengue virus NS1 antigen in human serum / plasma. This kit is for professional use and only for the initial screening test and reactive samples should be confirmed by a supplemental assay such as nucleic acid test and other immunological assays.

PRECAUTIONS
1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures.
4. Do not eat or smoke while handling specimens.
5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards.
6. Avoid splashing or aerosol formation.
7. Clean up spills thoroughly using an appropriate disinfectant.
8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container.
9. Do not mix and interchange different specimen.
10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch.
11. Do not use it beyond the expiration date.

Specimen Collection & Storage:
1. Specimen collection-
1) Serum/Plasma
Collect the whole blood into the collection tube (Not containing Anticoagulants such as heparin, EDTA, and sodium citrate) by Venipuncture, leave to settle for 30 minutes for blood coagulation and centrifuge blood to get serum specimen or supernatant.
2. Specimen storage-
All specimens should be tested as soon as they are prepared. If specimens are not immediately tested. They should be stored at 2~8 °C for 3 days, -20 °C for longer period than 3 days.

Storage & Expiry:
1) Dengue NS1 Antigen test should be stored between 4-30 C
2) Expiration date of this kit is 24 months after its manufacture date.

Procedure:
1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.)
2. Please perform the test immediately after removing the device from the foil pouch.
3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device.
4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes.

SKU: MK1100057 Category:

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.