• Lead acquisition : 12bit/1000Hz (synchronously 12 leads) Work mode : Manual/Auto/1-channel 60s compressed record/Rhythm analysis • Filter : Muscle filter: (25Hz/35Hz/45Hz/75Hz/100Hz,-3dB) • AC filter: (50Hz or 60Hz, -20dB) • Drift filter: (0.5Hz,-3dB) • CMRR : e*100dB (with AC Filter) • Input impedance : e*50M&! • Input circuit current : d*0.1µA • Patient current leakage : d*10µA • Calibrating voltage : 1mV±2% • Voltage tolerance : e*±500mV • Time constant : e*3.2s • Frequency response : 0.05~150Hz (-3db) • Noise level : < 15µVp-p • Inter-channel interference : d*0.5mm • Sensitivity : 1.25, 2.5, 5, 10, 20, 40mm/mV • Communication : RS232 / USB port • Power supply : AC 1 10-230V (±10%), 50/60HZ (±1 Hz), 60VA • DC Built-in rechargeable battery, 12.6V (1500mAh) • Weight : 2.25Kg • *Box Dimension : 410mm x 320mm x 240mm
Features: * The recorder can real-time store ECG data for 24-hour. * Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor s work. * With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms. * Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel. * Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis. * All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. * With many pacing analysis templates, such as Dual chamber pacing , Atrial pacing , Ventricular pacing , Ventricular Pseudofusion and Ventricular asynchronous pacing , etc. * Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function. * With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability. * One-key print, convenient and fast to print the reports. * Perfect case management function. * The risk of sleep breath pause can be predicted by the unique *Sleep breath pause syndrome*analysis function. * The death risk in patients with myocardial infarction can be predicted by the *HRT* analysis function. * T-Wave alternation is an important index to predict the malignant arrhythmia and sudden cardiac death
There are no reviews yet.